Vista de página 6
- T3 with temperature adapter -50 +200 °C
- T2, T1 with temperature adapter -50 +250 °C
On the electronics - category 1/2G or 2G
Temperature class
- T6 -40 +67 °C
- T5 -40 +82 °C
- T4, T3, T2, T1 -40 +90 °C
3.2.2 Permissible operating pressure in range of the sensor
Category 1/2G
Operating pressure 0.8 1.1 bar
Category 2G
Operating pressure Vaccum 64 bar (if necessary nominal
pressure of the process connection element)
Information:
The application conditions mentioned before also apply to LEVEL SWITCH LS8112.
C******N* with lock tting ARV8112.2** (Pmax. 16 bar, Tmax. 150 °C), ARV8112.3**
(Pmax. 64 bar, Tmax. 250 °C).
3.3 Permissible diering application conditions
The LEVEL SWITCH LS8111C******N*, LEVEL SWITCH LS8112C******N* (also with lock
tting ARV8112.***) can also be operated as category 1/2G instrument according to the
conditions mentioned below.
Temperature class Temperature on the sen-
sor
Ambient temperature on
the electronics
Process pressure
T4, T3, T2, T1 -20 +60 °C -40 +90 °C 0 6 bar
Note:
If the application conditions (as mentioned before) on the sensor dier, and LEVEL
SWITCH LS8111C******N*, LEVEL SWITCH LS8112C******N* is used as category
1/2G instrument, please make sure that the sensor (even in case of failure) has no
own heating and that the safe operation of the equipment in respect to pressures/
temperatures of the materials used, is subject to the user.
The permissible pressures and temperatures for operation are mentioned in the
operating instructions manuals.
LEVEL SWITCH LS8111.C******N*; LEVEL SWITCH LS8112.C******N* 7